HVAC/R Sensors
Temperature Sensors

Humidity Sensors
Pressure Sensors
Air Quality Sensors
HVAC Sensor Accessories
Sensor Specifications





Company Overview
Catalog/Price Book
Instruction Sheets
Ordering & Shipping

BAPI Distributor List
Contact Us

Building Automation Products, Inc.,
Tel: +1-608-735-4800
Fax: +1-608-735-4804

Copyright © 2007 BAPI

BAPI PRODUCT APPLICATION NOTES


Certification Forms

BAPI Certification Form Overview

Temp. Transmitter Calibration Certificate

Humidity Transmitter Calibration Certificate

Pressure Transmitter Calibration Certificate
Enclosure Styles

BAPI Enclosure Styles

NEMA Enclosure Rating Terminology

IEC Enclosure Rating Terminology

UL94 Flammability Rating Terminology
Ground Loop Problems:

Understanding Ground Loops

Avoiding Ground Loops
Zone Pressure Sensing:

Determining Air Flow in CFM


Pressure Terms Defined
Current Loops:

4-20 mA Current Loop Configurations
  (Five common 4-20 mA Configurations)

Understanding 4-20 mA Current Loops

Designing 4-20 mA Current Loops
  (Determining proper power supply voltage)
AC vs DC Power on Sensors:

Why BAPI recommends DC Power

Understanding Noise from AC Power
Mounting Outdoor Sensors
Proper placement and installation procedures for BAPI outdoor sensors
Understanding Full & Half Wave Power Supplies
Overview of the two types of power supplies and the dangers of mixing the two together.
Additional Setpoint Ranges
Complete list of setpoint output ranges for BAPI room units
BAPI Recommended Wire Lengths
Recommended wire lengths for 24 VAC or VDC sensor circuits for various wire gauges and maximum currents
BAPI Commits to RoHS Compliance
BAPI is committed to environmentally responsible manufacturing practices.
BAPI 100% Compatibility Guarantee
Guarantee of sensor compatibility with the HVAC system
RTD vs Thermistors
A comparison of the temperature measurement accuracy of RTD sensors vs thermistor sensors.
Measuring the Temp. of Small Pipes
Proper procedure for measuring water temperature using a remote probe strapped directly to the water pipe.
Thermistor Recertification
An overview of the thermistor recertification procedure
.
Using a Thermowell in Small Pipes
Procedure for using a Thermowell and 2-inch tee connector to measure the temperature of a two-inch water pipe.
Material Safety Datasheets
Why doesnt BAPI have Material Safety Data Sheets (MSDS) for their products?
Thermowells Explained
An overview of Thermowells and Immersion Probes, as well as their application and installation.
BAPI-Stat 2 Latching Display Options
9 LCD display options available on the BAPI-Stat 2 room unit if you select the “Override as a Latching Switch” (-L)
Humidity Sensor Service Life
An overview of the estimated life expectancy of a BAPI humidity sensor.
T1K Temperature Transmitter Ranges
Available and verified temperature ranges for the T1K RTD Transmitter
T100 Temperature Transmitter Ranges
Available and verified temperature ranges for the T100 RTD Transmitter




BAPI has help when you need it. Check out our library of Application Notes.